pasterindex.blogg.se

Asr-6405e 128mb sas vmware vsphere 6.5
Asr-6405e 128mb sas vmware vsphere 6.5




asr-6405e 128mb sas vmware vsphere 6.5
  1. #ASR 6405E 128MB SAS VMWARE VSPHERE 6.5 SERIAL#
  2. #ASR 6405E 128MB SAS VMWARE VSPHERE 6.5 UPDATE#

#ASR 6405E 128MB SAS VMWARE VSPHERE 6.5 UPDATE#

The new version is now ESXi 6.0 Build 4192238 Update 2 A03 Dell. The initial build was ESXi 6.0 Update 1B Build 3380124 A42 (Dell). Then, I realize the VMware ESXI 6.0 updates. I realized the upgrade via the LifeCycle Controller (Dell) with USB key. I generated a bundle of firmwares Windows 圆4 with the “Dell Repository Manager” tool. It was the version installed on each server however I met this problem.

asr-6405e 128mb sas vmware vsphere 6.5

#ASR 6405E 128MB SAS VMWARE VSPHERE 6.5 SERIAL#

The following table lists serial attached SCSI (SAS) HBAs that have been tested with the SC and SCv Series of array products:ĭell support indicates in the table the adapter firmware version for Dell adapter model (12Gb SAS) with VMware ESXi 6.0 is 09.17.20.17. Note: There is a VMware KB that describes Input/Output (I/O) driver support with VMware ESXi 6.0 and related implications for vSphere 6.0 only features. Upgrading VMware ESXi 6.0 build of each Dell R530 node.Upgrading firmwares speccialy 12Gb SAS Adapter of each Dell R530 server,.The VMware ESXi 6.0 operating system with the HBA that the server uses to send IO requests to the storage center and for mapping volumes. I have not found the solution on Internet so I will explain you below my point of view. The LSI 12Gb SAS card in the server (Dell R530, R630, R730 or others) was unknown by the server. I posted an article sometime ago about the case here.

asr-6405e 128mb sas vmware vsphere 6.5

When I did this operation with the correct HBAs and LUNs ID, the datastores have been mounted directly in ESXi hypervisors… Strange! 🙂įirst time, I thought the problem was the Dell Compellent storage but I remembered a similar thing with the 12 Gbps SAS cards. So, I tried to remove the cluster configuration (servers) of the SAN configuration via “Storage Manager” console and I recreate the servers inside. I checked the physical links and everything was alright. For information, the servers are connected to the Compellent storage with 12 Gbps SAS HBA cables. No error message appeared and the rescan of storage adapters and datastores since the “Configuration” tab of node didn’t work. When I tried to restart the environment composed of Dell R530 servers and Dell Compellent SCv 2020 SAN storage, the VMware ESXi hypervisors didn’t mount the datastores. The FUJITSU Server PRIMERGY RX2530 M4 is a dual-socket rack server that provides high performance of the new Intel ® Xeon ® Processor Scalable Family CPUs, expandability of up to 3TB of DDR4 memory, and up to 10x 2.5-inch storage devices - all in a 1U space saving housing. Basically, we stopped all the equipment to move them in a new building. This week, I moved the infrastructure of one of my customers in Paris.






Asr-6405e 128mb sas vmware vsphere 6.5